bay sssensoradaptivethresh
</Syntax>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Magnus_VLF</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
The value at which the plenum slipsheet sensor registers a slipsheet instead of a plate.
This value is dynamically updated by the Adaptive Slipsheet Threshold (AST) firmware
to automatically track changes in reflectivity due to changing plate stack height.
Setting this value to 0 disables the AST feature and causes the firmware to always
use the "PlenumSSSensorThresh" parameter.
</text></DescriptionText>
<DescriptionText><text>
If this parameter is NOT set to 0 then it is initialized to the "PlenumSSSensorThresh"
value each time the cassette is loaded.
</text></DescriptionText>
</Description>
<Availability>
<DescriptionText><text>
This parameter is available.
</text></DescriptionText>
</Availability>
<Default>
<UnnumberedList>
<li>Please issue the appropriate monitor command to determine this parameter's default value.</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 1023</li>
</UnnumberedList>
</Range>
<LastModified>
04-Aug-2005
</LastModified>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Access>
Normal
</Access>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:24:00 2008 PST
</Updated>
<Links>
</Links>
</Parameter>